1.000.000+ free PDF manuals from more than 10.000 brands. Search and view your manual for free or ask other product owners. Sprint 350 Three Phase kWh Meter Direct Connected The Sprint 350 advanced accumulation meter is an enhanced metering solution for three-phase direct-connected installations. It is suitable for domestic, industrial and commercial applications. Certificate of Approval NMI 14/2/84 Features Active, reactive and apparent energy measurement.
- Secure Meters Sprint 350 User Manual Instructions
- Secure Meters Sprint 350 User Manual Transmission
- Secure Meters Sprint 350 User Manual Download
- If you're wondering how to use the digital technology in the car, we have provided instructional How-To videos to guide you. Download them here.
- Sprint 350 is an enhanced metering solution for three- phase direct-connected installations. It is suitable for domestic, industrial and commercial applications. It has advanced revenue protection features, making it especially useful in areas where theft and fraud are prevalent.
If you are in Sri Lanka and you have got your self a net meter from CEB (Solar power), then its very likely that you have a Sprint 350 energy meter. Before we proceed any further, I like to say, this is the least intuitive electronic device I’ve ever seen.
Here are the steps to read the meter.
1. Wait till the display is automatically switched on (don’t press any buttons)
2. After display reset,
1st reading – [tue 14.09.16] – Current date
2nd reading – [tm 07.30.55] – Current time
3rd reading – [U 000753.5 kWh ->] – Current import energy reading
4th reading – [U 0002.32 kVA ->] – Up to now, max import demand seen for this month (in kVA)
5th reading – [U d04.09.16 ->] – Date when the above max import demand occurred
6th reading – [U tm13.10.00 ->] – Time when the above max import demand occurred
7th reading – [U 000725.2 kWh ->] – Imported energy reading for the previous month (before meter reset)
8th reading – [U 0002.73 kVA ->] – Max imported demand for previous month
9th reading – [U d28.08.16 ->] – Date when the above max import demand occurred (previous month)
10th reading – [U tm04.23.00 ->] – Time when the above max import demand occurred (previous month)
Secure Meters Sprint 350 User Manual Instructions
from 11th reading to 18th, same format follows for exported (generated) energy. Eg. 15th reading (same as 7th) will give you the Exported energy reading for the previous month.
Secure Meters Sprint 350 User Manual Transmission
Hope this gives some insight to what you need. Let me know if you have queries.
Harshana
Rate this project
Secure Meters Sprint 350 User Manual Download
17937total visits,6visits today